Dependence of the recurrence development on the sutures tension force while performance of laparoscopic cruroraphy

Clicks: 146
ID: 276536
2020
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #3 of 11 articles by views in Клінічна хірургія

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Objective. Intraoperative determination of the threads tension force while performance of laparoscopic cruroraphy. Materials and methods. Using a numerical dynamometer Walcom FM-204-50K the threads tension force was measured while performance of laparoscopic cruroraphy in 62 patients, suffering large hiatal hernias. The measured results have included a middle value of the tension force of every stitch for secure approximation of diaphragmatic crura and presence of any dehiscence in diaphragmatic crura while doing cruroraphy. Results. The middle tension force of the first suture while performing of posterior cruroraphy have constituted 2.1 N, while a second one – 3.2 N and the third – 4.2 N. Positive correlational dependence was revealed between the threads tension force while doing cruroraphy and the hiatus square, as well as with a patient’s age. The correlation link between the threads tension force, while doing cruroraphy, and the patient’s body mass index was not revealed. The diaphragmatic crura muscles dehiscence was observed in the threads tension force, exceeding 4 N. Conclusion. The sutures tension force while cruroraphy conduction, as our data demonstrate, exceeding 4,5 - 5 N, constitutes indication for the net implants application.
Reference Key
grubnik2020dependence Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Grubnik, V. V. ;Tkachenko, A. I. ;Grubnik, V. V. ;
Journal Клінічна хірургія
Year 2020
DOI
DOI not found
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.