IgG4-IgE complex interferes with measurement of IgE concentration.
Clicks: 199
ID: 276034
2022
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
30.0
/100
199 views
38 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #5 of 6 articles by views in Clinical biochemistry
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Patients with immunoglobulin G4 (IgG4)-related disease (IgG4-RD) have elevated immunoglobulin E (IgE) concentration compared to that in healthy individuals, which suggests the occurrence of IgE-mediated allergic reactions. We have previously shown that IgG4 and IgE form a complex in some patients with IgG4-RD. However, it is currently unknown whether and how the presence of the IgG4-IgE complex affects IgE concentration measurements by different assays.Twenty patients with confirmed presence or absence of IgG4-IgE complex were evaluated. We compared IgE concentrations measured by ST AIA-PACK IgE II (AIA-PACK), Elecsys IgE II Immunoassay (Elecsys), and Iatroace IgE (Iatroace) and evaluated to what extent the IgG4-IgE complex interfered with these measurements.In patients with the IgG4-IgE complex, IgE concentrations measured using Iatroace were significantly lower than those measured using Elecsys and tended to be lower than those measured using AIA-PACK. IgE concentrations determined by Iatroace were significantly different in patients with and without the IgG4-IgE complex, whereas no significant differences between these groups were detected when IgE concentrations were measured by AIA-PACK or Elecsys.The formation of the IgG4-IgE complex underestimates measured IgE concentrations depending on the method used. Therefore, caution should be exercised when selecting a specific IgE assay for patients with IgG4-RD.
| Reference Key |
nakano2022igg4igeclinical
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Nakano, Keiichi;Sugita, Junichi;Seimiya, Masanori;Yasuda, Keiko;Watanabe, Chiaki;Goto, Hideki;Teshima, Takanori; |
| Journal | Clinical biochemistry |
| Year | 2022 |
| DOI |
S0009-9120(22)00275-2
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.