Promoting the effect of microbubble-enhanced ultrasound on hyperthermia in rabbit liver.
Clicks: 264
ID: 275054
2022
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
30.0
/100
264 views
38 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #3 of 3 articles by views in Journal of medical ultrasonics (2001)
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
The heat-sink effect is one reason for the insufficient temperature increase in hyperthermia (HT) treatment for cancer. Microbubbles (MBs) nucleate inertial cavitation under therapeutic ultrasound (TUS) exposure, which form microbubble-enhanced ultrasound (MEUS), which results in blocking blood perfusion in the targeted liver tissues. This study aimed to determine if synergistic effects exist during HT in the liver when combined with MEUS.Forty rabbits with surgically exposed livers were randomly divided into TUS + MB + HT, MB + HT, normal saline + HT, and MB + sham groups (n = 10 in each group). Liver perfusion was evaluated using contrast-enhanced ultrasound. The temperatures of the liver tissues were monitored using thermocouples. Pathological changes were determined by hematoxylin and eosin (H&E) staining. Serum hepatic transaminases were evaluated.MEUS pretreatment almost completely blocked the perfusion of targeted areas. The TUS + MB + HT and MB + HT groups showed significantly higher temperatures in treated areas than those in the other groups. However, the TUS + MB + HT group exhibited a more stable and regular increase in temperatures in the fitting curves compared with the MB + HT group. H&E staining revealed swelling hepatocytes, hemorrhage, and thrombosis in the portal area in the TUS + MB + HT group.MEUS reduced the blood perfusion in the targeted liver tissues, and, therefore, overcame the heat-sink effect during the HT procedure in rabbits. MEUS pretreatment might have the potential to enhance the therapeutic effect of HT.
| Reference Key |
yang2022promotingjournal
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Yang, Yuwen;Luo, Huanqian;Zhao, Yang;Li, Lu;He, Yan;Xi, Fen;Jin, Hai;Gao, Ruru;Luo, Qiong;Liu, Jianhua; |
| Journal | Journal of medical ultrasonics (2001) |
| Year | 2022 |
| DOI |
10.1007/s10396-021-01187-y
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.