Calibration Proposal for UHF Partial Discharge Measurements at Power Transformers
Clicks: 147
ID: 274863
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
30.0
/100
147 views
26 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #197 of 220 articles by views in energies
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 220 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
The continuous, non-intermitted service of electrical grids relies on the reliability of their assets, e.g., power transformers. Local insulation defects can result in serve failures such as breakdowns with severe subsequent costs. The prevention of such events is crucial. Hence, partial discharge (PD) activity at power transformers is evaluated directly in the factory before shipment. Additionally, PD activity can be monitored during service using the ultra-high frequency (UHF) method. In this contribution, a calibration procedure is proposed for the UHF method. The calibration process is required to ensure both, reproducibility and comparability of UHF measurements: Only a calibrated UHF measurement procedure can be introduced supplementary to IEC 60270 in acceptance tests of power transformers. The proposed calibration method considers two factors: The influence of the UHF-antenna’s sensitivity and the PD recorder characteristics including accessories such as cable damping, pre-amplifier, etc. The former is addressed by a characterization of UHF sensors using the standard antenna factor (AF) in a gigahertz transverse electromagnetic (GTEM) cell. The PD recorder’s influence is corrected by using a defined, invariable test signal as reference for all recording devices. A practical evaluation of the proposed calibration procedure is performed in a laboratory setup using different UHF recording devices and UHF sensors using artificial PD signals and real voltage-driven PD sources.
| Reference Key |
siegel2019calibrationenergies
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Siegel, Martin;Coenen, Sebastian;Beltle, Michael;Tenbohlen, Stefan;Weber, Marc;Fehlmann, Pascal;Hoek, Stefan M.;Kempf, Ulrich;Schwarz, Robert;Linn, Thomas;Fuhr, Jitka; |