Temperature Difference Sensor to Monitor the Temperature Difference in Processor Active Heat Sink Based on Thermopile
Clicks: 184
ID: 274326
2021
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Emerging Content
30.0
/100
184 views
33 readers
AI Quality Assessment
Not analyzed
Readership in this journal
EmergingRanked #84 of 113 articles by views in Electronics
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
The monitoring of processor temperature is crucial to increase its efficiency. One of the novel approaches is use the information not only about the CPU (Central Processing Unit) thermal state, but also about changing environmental conditions. The additional temperature difference sensor to monitor thermal changes in the processor environment is necessary. The sensor dedicated for active heat sink, often used inside laptops, was designed, fabricated and investigated. To fulfill the requirements and to match to the specific shape of the active heat sink, the hybrid sensor was proposed. It was composed of six thermocouples and fabricated using thick-film and LTCC (Low Temperature Cofired Ceramic) technology combined with wire thermocouples. Thick-film/LTCC flat substrates with thermoelectric paths ensured good thermal contact between the sensor and the monitored surface. The thermoelectric wires allowed adjusting the sensor to the complicated shape of the active heatsink. Three different versions of the sensor were realized and compared. All of them seem to be suitable for measuring the temperature difference in the given application and they can be used in further works.
| Reference Key |
markowski2021electronicstemperature
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Piotr Marek Markowski;Mirosław Gierczak;Andrzej Dziedzic;Markowski, Piotr Marek;Gierczak, Mirosław;Dziedzic, Andrzej; |
| Journal | Electronics |
| Year | 2021 |
| DOI |
10.3390/electronics10121410
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org