Development of microwave-multiplexed superconductive detectors for the HOLMES experiment
Clicks: 254
ID: 273969
2016
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
30.0
/100
254 views
50 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #289 of 935 articles by views in journal of physics: conference series
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 935 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
In recent years, the progress on low temperature detector technologies has allowed design of large scale experiments aiming at pushing down the sensitivity on the neutrino mass below 1 eV. Even with outstanding performances in both energy (~eV on keV) and time resolution (~ 1 μs) on the single channel, a large number of detectors working in parallel is required to reach a sub-eV sensitivity. HOLMES is a new experiment to directly measure the neutrino mass with a sensitivity as low as 2eV. HOLMES will perform a calorimetric measurement of the energy released in the electron capture (EC) decay of 163 Ho. In its final configuration, HOLMES will deploy 1000 detectors of low temperature microcalorimeters with implanted 163 Ho nuclei. The baseline sensors for HOLMES are Mo/Cu TESs (Transition Edge Sensors) on SiNx membrane with gold absorbers. The readout is based on the use of rf-SQUIDs as input devices with flux ramp modulation for linearization purposes; the rf-SQUID is then coupled to a superconducting lambda/4-wave resonator in the GHz range, and the modulated signal is finally read out using the homodyne technique. The TES detectors have been designed with the aim of achieving an energy resolution of a few eV at the spectrum endpoint and a time resolution of a few micro-seconds, in order to minimize pile-up artifacts.
| Reference Key |
vale2016journaldevelopment
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Andrea Giachero,D Becker,D A Bennett,M Faverzani,E Ferri,J W Fowler,J D Gard,J P Hays-Wehle,G C Hilton,M Maino,J A B Mates,A Puiu,A Nucciotti,C D Reintsema,D S Swetz,J N Ullom,L R Vale;Andrea Giachero;D Becker;D A Bennett;M Faverzani;E Ferri;J W Fowler;J D Gard;J P Hays-Wehle;G C Hilton;M Maino;J A B Mates;A Puiu;A Nucciotti;C D Reintsema;D S Swetz;J N Ullom;L R Vale; |
| Journal | journal of physics: conference series |
| Year | 2016 |
| DOI |
10.1088/1742-6596/718/6/062020
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.