Vis-Fusion LIEXA: A Point-of-Care Testing Method for Highly Specific and Sensitive Quantitation of Fusion Gene with SmartPhone.

Clicks: 291
ID: 27377
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #43 of 194 articles by views in Analytical chemistry

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 194 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Fusion genes, playing a causal role in human tumorigenesis and developments, are deemed as gold standard molecular bi-omarkers in cancer diagnosis, therapy, and prognosis. A rapid, robust and sensitive method detection of fusion gene for point-of-care (POC) diagnosis is urgently needed. Here, taking the advantages of the superior specificity of ligation reaction and highly amplified efficiency of isothermal exponential amplification with pH indicator, we developed a colorimetric method for visual detection of fusion gene with high sensitivity and specificity by the naked eye. More importantly, we first found that fusion gene can be accurately quantified in a wide dynamic range (2 zmol to 2 fmol) by an open-source App with SmartPhone-assisted RGB (Red, Green, and Blue value) reading mode. The proposed method for Visual detection of Fu-sion gene by Ligation-triggered Isothermal Exponential Amplification is termed Vis-Fusion LIEXA. We have demonstrated that the Vis-Fusion LIEXA is a practical and reliable method for accurate quantitative detection of the fusion gene in a complex biological sample at zmol level in 40 min only with a SmartPhone, thereby providing a user-friendly and point-of-care testing (POCT) tool for molecular diagnostics.
Reference Key
wang2019visfusionanalytical Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Wang, Hui;Wang, Honghong;Jia, Yuting;Sun, Ruyan;Hong, Weixiang;Zhang, Mai;Li, Zhengping;
Journal Analytical chemistry
Year 2019
DOI
10.1021/acs.analchem.9b03061
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.