Accurate γ and MeV-electron track reconstruction with an ultra-low diffusion Xenon/TMA TPC at 10 atm

Clicks: 254
ID: 272861
2015
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #43 of 88 articles by views in nuclear instruments and methods in physics research section a: accelerators, spectrometers, detectors and associated equipment

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
We report the performance of a 10 atm Xenon/trimethylamine time projection chamber (TPC) for the detection of X-rays (30 keV) and γ-rays (0.511–1.275 MeV) in conjunction with the accurate tracking of the associated electrons. When operated at such a high pressure and in ~1%-admixtures, trimethylamine (TMA) endows Xenon with an extremely low electron diffusion (1.3±0.13mm-σ (longitudinal), 0.95±0.20mm-σ (transverse) along 1 m drift) besides forming a convenient ‘Penning-Fluorescent’ mixture. The TPC, that houses 1.1 kg of gas in its fiducial volume, operated continuously for 100 live-days in charge amplification mode. The readout was performed through the recently introduced microbulk Micromegas technology and the AFTER chip, providing a 3D voxelization of 8mm×8mm×1.2mm for approximately 10 cm/MeV-long electron tracks. Resolution in energy (ε) at full width half maximum (R) inside the fiducial volume ranged from R=14.6% (30 keV) to R=4.6%(1.275MeV). This work was developed as part of the R&D program of the NEXT collaboration for future detector upgrades in the search of the neutrino-less double beta decay (ββ0ν) in 136Xe, specifically those based on novel gas mixtures. Therefore we ultimately focus on the calorimetric and topological properties of the reconstructed MeV-electron tracks. In particular, the obtained energy resolution has been decomposed in its various contributions and improvements towards achieving the R=1.4%1MeV/ε levels obtained in small sensors are discussed.
Reference Key
veenhof2015nuclearaccurate Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors
Journal nuclear instruments and methods in physics research section a: accelerators, spectrometers, detectors and associated equipment
Year 2015
DOI
10.1016/j.nima.2015.08.033
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.