Soft X-ray-assisted detection method for airborne molecular contaminations (AMCs)

Clicks: 237
ID: 272580
2015
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #3 of 8 articles by views in journal of nanoparticle research

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Airborne molecular contaminations (AMCs) represent a wide range of gaseous contaminants in cleanrooms. Due to the unintentional nanoparticle or haze formation as well as doping caused by AMCs, improved monitoring and controlling methods for AMCs are urgent in the semiconductor industry. However, measuring ultra-low concentrations of AMCs in cleanrooms is difficult, especially, behind a gas filter. In this study, a novel detection method for AMCs, which is on-line, economical, and applicable for diverse AMCs, was developed by employing gas-to-particle conversion with soft X-ray, and then measuring the generated nanoparticles. Feasibility study of this method was conducted through the evaluations of granular-activated carbons (GACs), which are widely used AMC filter media. Sulfur dioxide (SO2) was used as an AMC for the feasibility study. Using this method, the ultra-low concentrations of SO2 behind GACs were determined in terms of concentrations of generated sulfuric acid (H2SO4) nanoparticles. By calculating SO2 concentrations from the nanoparticle concentrations using empirical correlation equations between them, remarkable sensitivity of this method to SO2 was shown, down to parts-per-trillions, which are too low to detect using commercial gas sensors. Also, the calculated SO2 concentrations showed good agreement with those measured simultaneously by a commercial SO2 monitor at parts-per-billions.
Reference Key
pui2015journalsoft Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ChangHyuk Kim,Zhili Zuo,Hartmut Finger,Stefan Haep,Christof Asbach,Heinz Fissan,David Y. H. Pui;ChangHyuk Kim;Zhili Zuo;Hartmut Finger;Stefan Haep;Christof Asbach;Heinz Fissan;David Y. H. Pui;
Journal journal of nanoparticle research
Year 2015
DOI
10.1007/s11051-015-2936-2
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.