X-ray detection with Micromegas with background levels below 10−6keV−1cm−2s−1

Clicks: 226
ID: 272525
2013
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #46 of 73 articles by views in journal of instrumentation

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Micromegas detectors are an optimum technological choice for the detection of low energy x-rays. The low background techniques applied to these detectors yielded remarkable background reductions over the years, being the CAST experiment beneficiary of these developments. In this document we report on the latest upgrades towards further background reductions and better understanding of the detectors' response. The upgrades encompass the readout electronics, a new detector design and the implementation of a more efficient cosmic muon veto system. Background levels below 10−6keV-1cm-2s-1 have been obtained at sea level for the first time, demonstrating the feasibility of the expectations posed by IAXO, the next generation axion helioscope. Some results obtained with a set of measurements conducted in the x-ray beam of the CAST Detector Laboratory will be also presented and discussed.
Reference Key
yildiz2013journalx-ray Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors S Aune,Ferran Casas Aznar,D Calvet,Theopisti Dafni,A Diago,F Druillole,G Fanourakis,E Ferrer-Ribas,J Galán,J A García,Antonios Gardikiotis,Javier Gracia Garza,T Geralis,I Giomataris,Hector Gomez,Diego Gonzalez Diaz,D C Herrera,F J Iguaz,Igor García Irastorza,D Jourde,G Luzón,H Mirallas,J P Mols,T Papaevangelou,Alex Rodriguez,L Seguí,A Tomás,T Vafeiadis,S C Yildiz;S Aune;Ferran Casas Aznar;D Calvet;Theopisti Dafni;A Diago;F Druillole;G Fanourakis;E Ferrer-Ribas;J Galán;J A García;Antonios Gardikiotis;Javier Gracia Garza;T Geralis;I Giomataris;Hector Gomez;Diego Gonzalez Diaz;D C Herrera;F J Iguaz;Igor García Irastorza;D Jourde;G Luzón;H Mirallas;J P Mols;T Papaevangelou;Alex Rodriguez;L Seguí;A Tomás;T Vafeiadis;S C Yildiz;
Journal journal of instrumentation
Year 2013
DOI
10.1088/1748-0221/8/12/c12042
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.