A Study of Non-uniform Pressure Distribution in Vacuum Chamber during Dynamic Gas Flow
Clicks: 159
ID: 271187
2009
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
30.0
/100
159 views
38 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #3 of 3 articles by views in Journal of the Korean Vacuum Society
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
진공챔버는 진공게이지 교정, 산업에서의 재료처리 등 여러 가지 다양한 용도에 맞게 적용이 가능하다. 이 진공챔버 내부에서 가스가 유입되는 과정에서의 진공도는 일정하게 유지하기가 힘들다. 산업체 응용에서뿐만 아니라 연구과정에서도 진공챔버 내부에 가스가 유입되는 동안의 내부압력분포와 최대도달 평형압력을 아는 것이 매우 중요하다. 이러한 진공챔버 내부의 압력 불균형을 감소시키기 위해서 가스 주입구 부분에 baffle을 이용하는 방법이 있다. 현재 지속적인 기체흐름이 있는 진공챔버 내부의 기체흐름의 작용에 관해 0.1 Pa~133 Pa 영역에서 불규칙한 압력을 최소화하기 위한 baffle plate의 효과에 대해 연구하였다. 최대편차는 가스 주입구 부분에서 나타나는 압력으로 baffle plate가 전환흐름영역에서 큰 영향을 미치는 것으로 나타났다.
Vacuum chambers have wide application for a variety of purposes such as material processing, vacuum gauge calibration, etc. As the dynamic pressure generated in such chamber is non-uniform, in many industrial as well as research processes, it is vital to know the non-uniform gas distribution with associated gas flow regimes and the ways of minimizing these pressure non-uniformities. In the present work, the behavior of gas flow in a vacuum chamber, during continuous gas flow, is described in the pressure range 0.1-133 Pa and the effect of baffle plate in minimizing the pressure non-uniformities is investigated. It was observed that maximum deviations in the pressure occur near the gas inlet point and that the effect of baffle plate in minimizing the pressure non-uniformities is more obvious in the transitional flow regime.
| Reference Key |
wakil2009journala
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Khan, Wakil;Hong, K.S.;Hong, S.S.;; |
| Journal | Journal of the Korean Vacuum Society |
| Year | 2009 |
| DOI |
DOI not found
|
| URL | |
| Keywords |
|
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org