Highly Sensitive Sensor Structure Based on Sol-Gel Waveguide Films and Grating Couplers

Clicks: 188
ID: 270469
2021
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #82 of 113 articles by views in Electronics

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
The technologies of optical planar evanescent wave chemical and biochemical sensors require chemically resistant, high refractive index waveguide films having very good optical transmission properties. In this paper we present such two-compound SiOx:TiOy waveguide films fabricated by using the sol-gel method and the dip-coating technique. These films not only have high optical quality and low propagation losses but also an extremely high refractive index of >1.90 (λ = 632.8 nm). Further we demonstrate efficient and simple sensing structures, designed and fabricated based on these films. For this purpose, grating couplers with a period of Λ = 417 nm were fabricated on the interface between a waveguide film and cover using the single-step nanoimprint method. These sensing structures were tested as planar refractometers. The results of the theoretical analysis on the basis of which the structures were designed as well as results of their experimental characterization are presented in this work. Consequently, the relationship between parameters and the sensitivity of investigated sensing structures is discussed. As a result, the profitable properties of the designed grating coupler sensors are verified and excellent consistency between the results of the theoretical analysis and experimental results is achieved.
Reference Key
karasiński2021electronicshighly Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Paweł Karasiński;Andrzej Kaźmierczak;Magdalena Zięba;Cuma Tyszkiewicz;Katarzyna Wojtasik;Paweł Kielan;Karasiński, Paweł;Kaźmierczak, Andrzej;Zięba, Magdalena;Tyszkiewicz, Cuma;Wojtasik, Katarzyna;Kielan, Paweł;
Journal Electronics
Year 2021
DOI
10.3390/electronics10121389
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.