A surrogate-based approach for trace organic chemical removal by a high-rejection reverse osmosis membrane.
Clicks: 218
ID: 26984
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
60.1
/100
218 views
179 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #539 of 637 articles by views in The Science of the total environment
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 637 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Public confidence in the safety of recycled water for potable water reuse can be improved by providing assurance regarding high removal of trace organic chemicals (TOrCs) by reverse osmosis (RO) treatment. This pilot-scale study assessed the effectiveness of a surrogate indicator-N-Nitrosodimethlyamine (NDMA)-for ensuring a high level of TOrC removal by a high-rejection RO membrane. The pilot-scale tests showed that the rejection of 23 TOrCs by the high-rejection RO membrane was consistently greater than NDMA rejection. In addition, NDMA rejection was highly correlated with TOrC rejection across varied operating conditions, indicating that NDMA can be used as a conservative surrogate indicator for TOrC removal. The RO treatment at a permeate flux of 20 L/m h and feed temperature of 13-27 °C resulted in as high as 75-87% NDMA rejection, which was considerably greater than a conventional low-pressure RO membrane (26-47%). However, the high-rejection RO membrane required a transmembrane pressure that was greater than that of the low-pressure RO membrane. Despite this disadvantage, this study suggests that the high-rejection RO membrane can effectively ensure a high level of TOrC removal (≥65%) when NDMA is used as a surrogate indicator, which cannot be ensured by assessing conventional conductivity rejection.
| Reference Key |
fujioka2019athe
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Fujioka, Takahiro;Takeuchi, Haruka;Tanaka, Hiroaki;Kodamatani, Hitoshi; |
| Journal | The Science of the total environment |
| Year | 2019 |
| DOI |
S0048-9697(19)33979-8
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.