Performance of an X-ray spectroscopic system based on a double-gate double-feedback charge preamplifier

Clicks: 96
ID: 269478
1999
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Popular

Ranked #85 of 88 articles by views in nuclear instruments and methods in physics research section a: accelerators, spectrometers, detectors and associated equipment

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
The performance of a near room temperature X-ray spectroscopic system is reported. The system is based on a charge preamplifier with the first transistor having two separated gates. The preamplifier operates in a continuous reset mode without any physical resistor connected to the input node. The leakage current and the current due to the rate of X-rays is neutralized by an average current of holes, flowing under the control of an additional feedback, from the bottom to the top gate. The preamplifier is followed by a simple circuit which exactly cancels the long tail of the impulse response of a pure double-gate preamplifier. The compensation of this tail, due to the very principle of the preamplifier's continuous reset through the double-gate mechanism, improves substantially the high-rate performance of the system. The preamplifier based on a commercially available double-gate front JFET MX-40 (MOXTEK) coupled to a silicon drift detector produced at BNL achieved ENC of 13 electrons at −30°C. The analysis of the system's performance, the noise analysis and optimization are described.
Reference Key
rehak1999nuclearperformance Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors A. Fazzi,P. Rehak;A. Fazzi;P. Rehak;
Journal nuclear instruments and methods in physics research section a: accelerators, spectrometers, detectors and associated equipment
Year 1999
DOI
10.1016/s0168-9002(99)00905-5
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.