Floating wetland islands as a method of nitrogen mass reduction: results of a 1 year test.

Clicks: 224
ID: 26916
2015
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Popular

Ranked #42 of 69 articles by views in water science and technology : a journal of the international association on water pollution research

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Floating wetland islands (FWIs) were tested in Pasco County, Florida, as a method of reducing total nitrogen (TN) in reclaimed water during reservoir storage. The Pasco County Master Reuse System (PCMRS) is a regional reclaimed-water transmission and distribution system providing wastewater effluent disposal for the county. Total daily mass loading from reclaimed water is limited by nitrogen content in the PCMRS watershed. To test TN reduction efficacy, 20 FWIs were constructed, installed, and monitored in a lined pond receiving PCMRS reclaimed water. In total, 149 m2 of FWIs were installed, distributed as a connected network covering 1,122 m2, or 7% of pond area. Pond hydraulic residence time averaged 15.7 days. Treatment performance was assessed during three consecutive periods: establishment (first 6 months of grow-in), performance (8 months immediately following grow-in), and control (3 months after the FWIs were removed from the pond). The FWIs enhanced pond nitrogen removal capacity by 32%. The primary effect of the FWIs was to decrease organic nitrogen in the pond outflow. By evaluating the difference between the performance and control periods, an incremental TN removal rate for the FWIs was calculated to be 4.2 kg N/m2 FWI per year.
Reference Key
vzquezburney2015floatingwater Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Vázquez-Burney, Rafael;Bays, James;Messer, Ryan;Harris, Jeffrey;
Journal water science and technology : a journal of the international association on water pollution research
Year 2015
DOI
10.2166/wst.2015.235
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.