Side-by-side comparison of 15 pilot-scale conventional and intensified subsurface flow wetlands for treatment of domestic wastewater.

Clicks: 308
ID: 26907
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #399 of 637 articles by views in The Science of the total environment

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 637 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
This study reports a systematic assessment of treatment efficacy for 15 pilot-scale subsurface flow constructed wetlands of different designs for CBOD, TSS, TOC, TN, NH-N, NO-N, NO-N, and E. coli over the course of one year in an outdoor study to evaluate the effects of design and plants. The systems consisted of a range of designs: horizontal flow (HF) with 50 and 25 cm depth, unsaturated vertical flow (VF) with sand or fine gravel, and intensified systems (horizontal and saturated vertical flow with aeration, and reciprocating fill and drain). Each system was built in duplicate: one was planted with Phragmites and one was left unplanted (with the exception of the reciprocating system, of which there was only one and it was unplanted). All systems were fed with the same primary-treated domestic wastewater. Effluent concentrations, areal and volumetric mass removal rates, and percent mass removal for the 15 systems are discussed. HF wetlands removed CBOD, TSS, TN, NH-N and E. coli by 73-83%, 93-95%, 17-41%, 0-27% and 1.5 log units, respectively. Unsaturated VF and aerated VF wetlands removed CBOD, TSS, TN, NH-N and E. coli by 69-99%, 76-99%, 17-40%, 69-99% and 0.9-2.4 log units, respectively. The aerated HF and reciprocating systems removed CBOD, TSS, TN, NH-N and E. coli by 99%, 99%, 43-70%, 94-99% and 3.0-3.8 log units, respectively. The aerated HF and reciprocating systems achieved the highest TN removal rate of all of the designs. Design complexity clearly enhanced treatment efficacy (HF < VF < Intensified, p < 0.001) during the first two years of plant growth while the presence of plants had minor effects on TN and NH-N removal in the shallow HF design only.
Reference Key
nivala2019sidebysidethe Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors
Journal The Science of the total environment
Year 2019
DOI
S0048-9697(18)35010-1
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.