Modeling the relationship of aeration, oxygen transfer and treatment performance in aerated horizontal flow treatment wetlands.

Clicks: 246
ID: 26905
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #95 of 168 articles by views in Water research

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 168 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Mechanical aeration is commonly used to improve the overall treatment efficacy of constructed wetlands. However, the quantitative relationships of air flow rate (AFR), water temperature, field oxygen transfer and treatment performance have not been analyzed in detail until today. In this study, a reactive transport model based on dual-permeability flow and biokinetic formulations of the Constructed Wetland Model No. 1 (CWM1) was developed and extented to 1) simulate oxygen transfer and treatment performance for organic carbon and nitrogen of two pilot-scale horizontal flow (HF) aerated wetlands (Test and Control) treating domestic sewage, and, 2) to investigate the dependence of oxygen transfer and treatment performance on AFR and water temperature. Both pilot-scale wetlands exhibited preferential flow patters and high treatment performance for chemical oxygen demand (COD) and NH-N at AFRs of 128-700 L m h. A reduction of the AFR in the Test system from 128 to 72 L h m substantially inhibited NH-N removal. Conservative tracer transport as well as reactive transport of dissolved oxygen (DO), soluble and total chemical oxygen demand (COD, COD), NH-N and NO-N measured in pilot-scale experiments were simulated with acceptable accuracy (E¯=0.39±0.26). An equation to estimate the volumetric oxygen transfer coefficient was found to be: k=0.511ln(AFR). Simulated treatment performance depended on k in a non-linear manner. A local sensitivity analysis of the calibrated parameters revealed porosity, hydraulic permeability and dispersion length of the fast flow field as well as k as most important. An optimal AFR for a spatially and temporally continuous aeration pattern for treatment wetlands treating similar influent was estimated to 150-200 L h m. This study provides insights into aeration mechanisms of aerated treatment wetlands and highlights the benefits of process modeling for in-depth system analysis.
Reference Key
boog2019modelingwater Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Boog, Johannes;Kalbacher, Thomas;Nivala, Jaime;Forquet, Nicolas;van Afferden, Manfred;Müller, Roland A;
Journal Water research
Year 2019
DOI
S0043-1354(19)30201-5
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.