Silicon Photomultipliers for Deep Tissue Cerenkov Emission Detection During External Beam Radiotherapy
Clicks: 331
ID: 268812
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
72.7
/100
331 views
244 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #1 of 2 articles by views in ieee photonics journal
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Cerenkov Emission (CE) during external beam radiation therapy (EBRT) from a linear accelerator (Linac) has been demonstrated as a useful tool for radiotherapy quality assurance and potentially other applications for online tracking of tumors during treatment delivery. However, some of the current challenges that are impacting the potential of CE are related to the limited detection sensitivity and the lack of flexible tools to fit into an already complex treatment delivery environment. Silicon photomultiplier (SiPM) solid-state devices are new promising tools for low light detection due to their extreme sensitivity that mirrors photomultiplier tubes and yet have a form factor that is similar to silicon photodiodes, allowing for improved flexibility in device design that may help in the process of wider clinical applicability. In this paper, we assess the feasibility of using SiPMs to detect CE during EBRT from a Linac and contrast their performance with commercially available silicon photodiodes (PDs). We demonstrate the feasibility of the SiPM-based probes for standard dosimetry measurements. We also demonstrate that CE optical signals can be detected from tissue depths about five times greater than that for standard probes based on PDs, making our SiPM probe an enabling technology of CE measurements, particularly for deep tissue applications.
| Reference Key |
oraiqat2019siliconieee
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Oraiqat, Ibrahim;DeBruin, Samuel;Pearce, Robin;Como, Christopher;Mikell, Justin;Taylor, Charles;Way, John;Suarez, Manuel;Rehemtulla, Alnawaz;Clarke, Roy;Naqa, Issam El; |
| Journal | ieee photonics journal |
| Year | 2019 |
| DOI |
DOI not found
|
| URL | |
| Keywords |
chemistry
Therapeutics. Pharmacology
Biology (General)
Chemical technology
Engineering (General). Civil engineering (General)
Information technology
Technology
Computer applications to medicine. Medical informatics
Science (General)
Science
Agriculture (General)
physics
optics. light
neoplasms. tumors. oncology. including cancer and carcinogens
applied optics. photonics
|
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.