Estimation of Left Ventricular Ejection Fraction by Semiautomated Edge Detection.
Clicks: 259
ID: 268613
1998
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Star Article
30.0
/100
259 views
30 readers
AI Quality Assessment
Not analyzed
Readership in this journal
StarRanked #3 of 3 articles by views in echocardiography
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Left ventricular (LV) volume and ejection fraction estimation from two-dimensional echocardiograms requires off-line analysis and time-consuming manual tracing. LV volumes may be estimated on-line with a semiautomated edge detection echocardiographic system [also known as acoustic quantification (AQ)], but there are few data that compare volumes obtained from the AQ method with volumes derived from off-line manual tracing of conventional two-dimensional echocardiograms. Echocardiograms were performed in 48 patients at two medical centers. LV volumes were measured from the apical view with the method of discs and area-length formulae and from the parasternal short-axis view with the modified ellipsoid model. Based on the criterion of >/=75% endocardial visualization, 25 (52%) of the short-axis views and 14 (29%) of the apical views were analyzed by a single investigator. End-diastolic and end-systolic LV volumes derived on line with the AQ system showed a very strong linear association with off-line, manually traced volumes (r = 0.96-0.99). Correlations for ejection fraction also were strong (r = 0.90-0.96). End-diastolic and end-systolic LV volumes, measured from the apical views, were underestimated by the AQ method. However, because the error was in the same direction, ejection fractions measured with the AQ system and by manual tracing of conventional echocardiograms were similar. Estimation of ejection fraction using a semiautomated edge detection echocardiographic system is a promising method for noninvasive evaluation of systolic function in carefully selected patients.
| Reference Key |
pérez1998echocardiographyestimation
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Byron F. Vandenberg,Hiram Cardona,James G. Miller,Trudy L. Burns,David J. Skorton,Julio E. Pérez;Byron F. Vandenberg;Hiram Cardona;James G. Miller;Trudy L. Burns;David J. Skorton;Julio E. Pérez; |
| Journal | echocardiography |
| Year | 1998 |
| DOI |
10.1111/j.1540-8175.1998.tb00671.x
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.