Axial black blood turbo spin echo imaging of the right ventricle

Clicks: 261
ID: 267243
2009
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Popular

Ranked #10 of 13 articles by views in Magnetic resonance in medicine

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Black blood turbo spin echo (TSE) imaging of the right ventricle (RV) free wall is highly sensitive to cardiac motion, frequently resulting in nondiagnostic images. Temporal and spatial parameters of a black blood TSE pulse sequence were evaluated for visualization of the RV free wall. Seventy‐four patient studies were retrospectively evaluated for the effects of acquisition timing on image quality. Axial black blood TSE images were acquired on 10 healthy volunteers to assess the role of spatial misregistration on right ventricle visualization; increasing the double inversion recovery (DIR) slice thickness beyond 300% had no effect on image quality (P = 0.2). Thirty‐five patient studies were prospectively evaluated with inversion times (TIs) corresponding to the mid‐diastolic rest period and end‐systole based on visual analysis of a four chamber cine. When TIs were chosen to be within the patients' RV rest period, mean image quality score was significantly improved (2.3 vs 1.86; P < 0.001) and the number of clinically diagnostic images increased from 32% to 46%. Black blood TSE imaging of the RV free wall is highly sensitive to cardiac motion. Image quality can be improved by choosing TIs concordant with the rest period of the patient's RV that may occur at mid‐diastole or end‐systole. Magn Reson Med 61:307–314, 2009.
Reference Key
bluemke2009magneticaxial Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Seth J. Berkowitz,Robson Macedo,Ashkan A. Malayeri,Steven M. Shea,Christine H. Lorenz,Hugh Calkins,Jens Vogel-Claussen,Harikrishna Tandri,David A. Bluemke;Seth J. Berkowitz;Robson Macedo;Ashkan A. Malayeri;Steven M. Shea;Christine H. Lorenz;Hugh Calkins;Jens Vogel-Claussen;Harikrishna Tandri;David A. Bluemke;
Journal Magnetic resonance in medicine
Year 2009
DOI
10.1002/mrm.21864
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.