Fluorescence Chemosensory Determination of Cu2+ Using a New Rhodamine–Morpholine Conjugate

Clicks: 449
ID: 2669
2017
Free PDF
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #8 of 81 articles by views in chemosensors

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
A new rhodamine-B carbonyl-morpholine derivative (denoted as RECM) was prepared by a two-step synthesis procedure. The employed method allowed a lactam ring development of rhodamine-B and ethylenediamine to demonstrate a facile amide bond formation. The obtained RECM was confirmed by 1H NMR, 13C NMR, and mass spectrometry analysis. RECM was formed to detect copper ion (Cu2+) due to its problematic toxicity features in aquatic ecosystems. It showed a high selectivity toward Cu2+ in comparison with some environmentally relevant alkali, alkaline earth, and transition metal cations at 50 µM in acetonitrile. Moreover, non-fluorescent RECM showed fluorescence intensity and UV-Vis absorbance increases in the presence of Cu2+ with high linear dependent coefficients (R2 = 0.964 and R2 = 0.982 respectively) as well as a color change from colorless to pink owing to the ring opening of the rhodamine spirolactam form. Binding capability experiments presented a clear 1:1 stoichiometry of RECM–Cu2+ complex with the binding constant (Ka) as 2.25 × 104 M−1. The calculation of limits of detection (LOD) was 0.21 µM based on the linear regression method, which is below the maximum contaminant level goal (MCLG) value of Cu2+ (1.3 ppm equals to 20.46 µM) in drinking water. These characteristics make the RECM a promising candidate for the real-time detection of toxic Cu2+ in environmental monitoring applications.
Reference Key
shekari2017fluorescencechemosensors Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors
Journal chemosensors
Year 2017
DOI
DOI not found
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.