Synthesis, characterization, solid-state structures, and spectroscopic properties of two catechol-based luminescent chemosensors for biologically relevant oxometalates.

Clicks: 258
ID: 2666
2007
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Popular

Ranked #46 of 86 articles by views in Inorganic chemistry

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
The new heteroditopic ligand 2,3-dihydroxy-N-(1,10-phenanthroline-5-yl)benzamide (H2-L3) was synthesized and coordinated to [Ru(bpy)2(phen)]2+- and [ReBr(CO)3(phen)]-type luminophores (bpy = 2,2'-bipyridine and phen = 1,10-phenanthroline). The resulting chemosensors [Ru(bpy)2(H2-L3)]2+ and [ReBr(CO)3(H2-L3)] were fully characterized and their solid-state structures and spectroscopic properties were investigated to assess how the photophysical properties of the luminescent signaling units affect the performance of the sensors. [Ru(bpy)2(H2-L3)]2+ and [ReBr(CO)3(H2-L3)] both signal the presence and concentration of molybdate and vanadate in aqueous acetonitrile through a decrease in emission intensity. [ReBr(CO)3(H2-L3)] also detects tungstate. Due to the higher emission intensity of the Ru-based sensor, its detection limits for molybdate (43 microg L(-1)) and vanadate (24 microg L(-1)) are almost 1 order of magnitude lower than the ones achieved with the Re-based sensor. The optimum working pH of the chemosensors is determined by the pKa values of the 2-hydroxy-groups of the receptor units: pH 4 for [ReBr(CO)3(H2-L3)] and pH 3 for [Ru(bpy)2(H2-L3)]2+. Both sensors are selective: equimolar amounts of PO4(3-), SO4(2-), ReO4-, Mn(II), Fe(III), Co(II), Ni(II), Cu(II), and Zn(II) do not interfere with the detection of molybdate or vanadate.
Reference Key
batey2007synthesisinorganic Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Batey, Helen D;Whitwood, Adrian C;Duhme-Klair, Anne-K;
Journal Inorganic chemistry
Year 2007
DOI
DOI not found
URL URL not found
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.