Synthesis, characterization, solid-state structures, and spectroscopic properties of two catechol-based luminescent chemosensors for biologically relevant oxometalates.
Clicks: 258
ID: 2666
2007
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Popular Article
77.3
/100
258 views
212 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
PopularRanked #46 of 86 articles by views in Inorganic chemistry
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
The new heteroditopic ligand 2,3-dihydroxy-N-(1,10-phenanthroline-5-yl)benzamide (H2-L3) was synthesized and coordinated to [Ru(bpy)2(phen)]2+- and [ReBr(CO)3(phen)]-type luminophores (bpy = 2,2'-bipyridine and phen = 1,10-phenanthroline). The resulting chemosensors [Ru(bpy)2(H2-L3)]2+ and [ReBr(CO)3(H2-L3)] were fully characterized and their solid-state structures and spectroscopic properties were investigated to assess how the photophysical properties of the luminescent signaling units affect the performance of the sensors. [Ru(bpy)2(H2-L3)]2+ and [ReBr(CO)3(H2-L3)] both signal the presence and concentration of molybdate and vanadate in aqueous acetonitrile through a decrease in emission intensity. [ReBr(CO)3(H2-L3)] also detects tungstate. Due to the higher emission intensity of the Ru-based sensor, its detection limits for molybdate (43 microg L(-1)) and vanadate (24 microg L(-1)) are almost 1 order of magnitude lower than the ones achieved with the Re-based sensor. The optimum working pH of the chemosensors is determined by the pKa values of the 2-hydroxy-groups of the receptor units: pH 4 for [ReBr(CO)3(H2-L3)] and pH 3 for [Ru(bpy)2(H2-L3)]2+. Both sensors are selective: equimolar amounts of PO4(3-), SO4(2-), ReO4-, Mn(II), Fe(III), Co(II), Ni(II), Cu(II), and Zn(II) do not interfere with the detection of molybdate or vanadate.
| Reference Key |
batey2007synthesisinorganic
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Batey, Helen D;Whitwood, Adrian C;Duhme-Klair, Anne-K; |
| Journal | Inorganic chemistry |
| Year | 2007 |
| DOI |
DOI not found
|
| URL | URL not found |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.