A fluid-immersed multi-body contact finite element formulation for median nerve stress in the carpal tunnel.
Clicks: 351
ID: 265285
2007
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Popular Article
30.0
/100
351 views
51 readers
AI Quality Assessment
Not analyzed
Readership in this journal
PopularRanked #5 of 5 articles by views in Computer methods in biomechanics and biomedical engineering
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Carpal tunnel syndrome (CTS) is among the most important of the family of musculoskeletal disorders caused by chronic peripheral nerve compression. Despite the large body of research in many disciplinary areas aimed at reducing CTS incidence and/or severity, means for objective characterization of the biomechanical insult directly responsible for the disorder have received little attention. In this research, anatomical image-based human carpal tunnel finite element (FE) models were constructed to enable study of median nerve mechanical insult. The formulation included large-deformation multi-body contact between the nerve, the nine digital flexor tendons, and the carpal tunnel boundary. These contact engagements were addressed simultaneously with nerve and tendon fluid-structural interaction (FSI) with the synovial fluid within the carpal tunnel. The effects of pertinent physical parameters on median nerve stress were explored. The results suggest that median nerve stresses due to direct structural contact are typically far higher than those from fluid pressure.
| Reference Key |
ko2007acomputer
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Ko, Cheolwoong;Brown, Thomas D; |
| Journal | Computer methods in biomechanics and biomedical engineering |
| Year | 2007 |
| DOI |
DOI not found
|
| URL | URL not found |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.