Radiopacity quantification and spectroscopic characterization of OrthoMTA and RetroMTA.
Clicks: 245
ID: 264714
2020
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Emerging Content
30.0
/100
245 views
38 readers
AI Quality Assessment
Not analyzed
Readership in this journal
EmergingRanked #12 of 15 articles by views in Microscopy research and technique
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
The aim of this article was to investigate the unknown radiopacity performances of OrthoMTA and RetroMTA via means of a contemporary image analyzing methods and energy dispersive X-ray spectroscopy. Three commercial hydraulic calcium silicate-based cements and a calcium hydroxide-based paste were used. Pure-grade zirconium oxide, bismuth oxide, zinc oxide, barium sulfate, and calcium hydroxide were as references. An energy-dispersive X-ray spectroscopy instrument was used for the elemental analysis. Radiographic image data was obtained according to the International Organization for Standardization 6876-2012 specifications. The region of interest was determined for each specimen. Mean (±SD) grey values of the X-ray image data was measured with an image analyzing software. The calibration curve was created by curve-plotting software and the mean grey-values were matched versus Al values (mm Al). Data were analyzed with one-way ANOVA followed by Tukey's multiple comparison test. Spectroscopic characterization of the commercial materials was shown with assigned Carbon, oxygen, aluminum, silicon, calcium, zinc, zirconium, barium, tungsten, bismuth, and sulfur elements. The major radiopacifier/s of OrthoMTA is Bi, of RetroMTA is Zr, of BioDentine are Ba and Zr, and of ProCal is Ba. The radiopacity values of all commercial materials are significantly different (p < .05). The rank of the radiopacity values: RetroMTA (3.36 ± 0.29mmAl) > OrthoMTA (2.56 ± 0.19mmAl) > BioDentine (2.02 ± 0.12mmAl) > ProCal (1.46 ± 0.60mmAl). The study reported that the radiopacity values and spectral characterization of RetroMTA and OrthoMTA cements. The pixel-based and reproducible method could be used universally to the quantification of the radiodensity of digitally collected X-ray data.
| Reference Key |
orhan2020radiopacitymicroscopy
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Orhan, Ekim Onur;Irmak, Özgür;Bal, Emine Zeynep;Danacı, Zeliha;Babayeva, Fidan;Orhan, Eren;Yücel, Berk Can; |
| Journal | Microscopy research and technique |
| Year | 2020 |
| DOI |
10.1002/jemt.23682
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.