Heating-stability, physical and chemical analysis of calcium silicate-based endodontic sealers.

Clicks: 225
ID: 264700
2021
Article Quality & Performance Metrics
Overall Quality Improving Quality
0.0 /100
Combines engagement data with AI-assessed academic quality
AI Quality Assessment
Not analyzed
Abstract
To evaluate possible modifications in root canal sealers subjected to a variety of heating conditions using vibrational spectroscopy and analysis of physical and chemical properties.EndoSequence BC Sealer HiFlow, Bio-C Sealer, BioRoot RCS, and AH Plus were analysed chemically using Raman spectroscopy (25-220 °C) and Fourier-transform infrared spectroscopy (FT-IR) (37-100 °C ). For FT-IR, the materials were tested individually and mixed with root dentine powder. Scanning electron microscopy (SEM) and coupled-energy dispersive spectroscopy (EDS) were used to evaluate surface and chemical elements. ISO 6876-2012 specifications were followed to evaluate flow, setting time (moist and dry), solubility, radiopacity. Also, pH analysis at 37 °C and 100 °C was performed. Shapiro-Wilk and Mixed ANOVA (within and between the effects of the subjects), Levene, and a post hoc analyses with Bonferroni correction were performed (P < 0.05).Vibrational spectroscopy exhibited peaks of tricalcium silicate, dicalcium silicate, and zirconium dioxide. Chemical changes in the Raman spectra during heating were discrete, as the inorganic-content predominated the signaling for all root canal sealers. FT-IR analysis exhibited spectral changes in water absorption for EndoSequence BC Sealer HiFlow and Bio-C Sealer, probably related to dehydration. For BioRoot RCS and AH Plus, no significant chemical changes were observed. Bio-C Sealer exhibited a band of polyethylene glycol band only after heating at 100 °C, probably related to its thermal decomposition. SEM/EDS analysis corroborated the composition results observed in vibrational spectroscopy for all materials. Heating at 100 °C significantly changed the flowability of all calcium silicate-based sealers with a wide variation in setting times at both temperatures, along with solubility levels above ISO-standard. For all tested sealers, radiopacity fulfilled the requirements, and pH exhibited alkaline values.The tested calcium silicate-based sealers were affected by heating. Calcium silicate-based root canal sealers exhibited high solubility which may represent a concern regarding their clinical use. AH Plus was the only root canal sealer that was stable after heating.
Reference Key
antunes2021heatingstabilityinternational Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Antunes, Tbm;Janini, Acp;Pelepenko, L E;Abuna, G F;Paiva, E M;Sinhoreti, Mac;Raimundo, I M;Gomes, Bpfa;de-Jesus-Soares, A;Marciano, M A;
Journal International endodontic journal
Year 2021
DOI
10.1111/iej.13496
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.