Simple and Efficient Detection Approach of Quercetin from Biological Matrix by Novel Surface Imprinted Polymer Based Magnetic Halloysite Nanotubes Prepared by a Sol-Gel Method.
Clicks: 261
ID: 263920
2021
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Emerging Content
30.0
/100
261 views
47 readers
AI Quality Assessment
Not analyzed
Readership in this journal
EmergingRanked #7 of 14 articles by views in Journal of chromatographic science
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Molecular imprinted polymers coated magnetic halloysite nanotubes (MHNTs-MIPs) were prepared through sol-gel method by using quercetin (Que), APTES and TEOS as template, monomer and cross-linker agent, respectively. The synthesized MHNTs-MIPs were characterized by fourier transform infrared, scanning electron microscope, transmission electron microscope, XRD and vibrating sample magnetometer. Various parameters influencing the binding capacity of the MHNTs-MIPs were investigated with the help of response surface methodology. Selectivity experiments showed that the MHNTs-MIPs exhibited the maximum selective rebinding to Que. Therefore, the MHNTs-MIPs was applied as a solid-phase extraction adsorbent for the extraction and preconcentration of quercetin and luteolin in serum and urine samples. The limits of detection for quercetin and luteolin range from 0.51 to 1.32 ng mL-1 in serum and from 0.23 to 1.05 ng mL-1 in urine, the recoveries are between 95.20 and 103.73% with the RSD less than 5.77%. While the recovery hardly decreased after several cycles. The designed MHNTs-MIP with high affinity, sensitivity and maximum selectivity toward Que in SPE might recommend a novel method for the extraction of flavonoids in other samples like natural products.
| Reference Key |
fizir2021simplejournal
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Fizir, Meriem;Dahiru, Nasiru Sintali;Cui, Yanru;Zhi, Hao;Dramou, Pierre;He, Hua; |
| Journal | Journal of chromatographic science |
| Year | 2021 |
| DOI |
bmaa120
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.