Earthquake loss estimation of residential buildings in Bantul regency, Indonesia.
Clicks: 279
ID: 26240
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
81.6
/100
279 views
224 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #16 of 29 articles by views in jamba (potchefstroom, south africa)
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Bantul regency in 2006 had experienced considerable earthquake and suffered many casualties. The factors such as high population density and lack of seismic design of residential buildings in Bantul besides its location in a high seismic region have increased its vulnerability to earthquake disasters that can lead to a widespread economic losses and casualties. This research aims to capture earthquake risk in Bantul towards economic losses and casualties by using risk curve. Risk curve is a combination of several sources from literatures containing hazard curve and vulnerability curve together with exposure. The result showed that the expected economic loss in 50 years for residential building is $647.22 million; however, the highest value of economic losses shows the value up to $7600m which occurs in earthquake of 7.15 M scale. The same worst-case scenario caused the casualties up to 49 000 people at night-time and 15 000 people at daytime. The result established that confined masonry building type conduces the highest value of economic losses and timber frame building shows the highest vulnerability to the earthquake disaster than other building types. Furthermore, in order to reduce the risk, we applied the hypothetical policy to build a simple earthquake-resistant house called Simple Instant Healthy House. The result indicates that this mitigation policy can effectively reduce both economic losses and casualties.
| Reference Key |
aulady2019earthquakejamba
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Aulady, Mohamad F N;Fujimi, Toshio; |
| Journal | jamba (potchefstroom, south africa) |
| Year | 2019 |
| DOI |
10.4102/jamba.v11i1.756
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.