Facile and recyclable dopamine sensing by a label-free terbium(III) metal-organic framework.
Clicks: 284
ID: 260978
2021
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Emerging Content
30.0
/100
284 views
32 readers
AI Quality Assessment
Not analyzed
Readership in this journal
EmergingRanked #97 of 391 articles by views in Talanta
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 391 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Herein, we present a facile strategy for dopamine (DA) sensing by a water-stable MOF of {[Tb(Cmdcp)(HO)](NO)·5HO} (1, HCmdcpBr = N-carboxymethyl-(3,5-dicarboxyl)pyridinium bromide). Without any post-modification, MOF 1 functions as an effective fluorescent sensor for the label-free detection of DA with the detection limit of 0.41 μM (S/N = 3). Under the optimum condition of 80 °C, pH 9 for 80 min in Tris-HCl with natural ambient oxygen, DA polymerizes to give polydopamine (pDA), which adheres to the surface of MOF 1 and quenched its green luminescence thoroughly. The sensing process is visible to naked eyes under 365 nm UV light irradiation due to the partial overlap of its excitation spectrum with the absorption spectrum of pDA. The sensing process is not interfered by coexisting of bio-related organic substances, such as glucose (Glu), 5-hydroxytryptamine (5-HT), homocysteine (Hcy), ascorbic acid (AA), uric acid (UA), cysteine (Cys), glutathione (GSH), as well as the presence of metal ions, including Zn, Ca, Mg, Ni and Co. The sensing process is also adaptable in biological fluids of serum and urine with satisfactory recoveries ranging from 96.14% to 104.32%.
| Reference Key |
wu2021faciletalanta
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Wu, Ke-Yang;Chen, Ming;Huang, Nai-Hai;Li, Rong-Tian;Pan, Wei-Lun;Zhang, Wen-Hua;Chen, Wen-Hua;Chen, Jin-Xiang; |
| Journal | Talanta |
| Year | 2021 |
| DOI |
S0039-9140(20)30690-1
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.