Near Real-Time Detection of E. coli in Reclaimed Water
Clicks: 311
ID: 260862
2018
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Emerging Content
0.3
/100
311 views
1 readers
AI Quality Assessment
Not analyzed
Readership in this journal
EmergingRanked #440 of 1,694 articles by views in sensors
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 1,694 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Advanced treatment of reclaimed water prior to potable reuse normally results in the inactivation of bacterial populations, however, incremental treatment failure can result in bacteria, including pathogens, remaining viable. Therefore, potential microorganisms need to be detected in real-time to preclude potential adverse human health effects. Real-time detection of microbes presents unique problems which are dependent on the water quality of the test water, including parameters such as particulate content and turbidity, and natural organic matter content. In addition, microbes are unusual in that: (i) viability and culturability are not always synonymous; (ii) viability in water can be reduced by osmotic stress; and (iii) bacteria can invoke repair mechanisms in response to UV disinfection resulting in regrowth of bacterial populations. All these issues related to bacteria affect the efficacy of real-time detection for bacteria. Here we evaluate three different sensors suitable for specific water qualities. The sensor A is an on-line, real-time sensor that allows for the continuous monitoring of particulates (including microbial contaminants) using multi-angle-light scattering (MALS) technology. The sensor B is a microbial detection system that uses optical technique, Mie light scattering, for particle sizing and fluorescence emission for viable bacteria detection. The last sensor C was based on adenosine triphosphate (ATP) production. E. coli was used a model organism and out of all tested sensors, we found the sensor C to be the most accurate. It has a great potential as a surrogate parameter for microbial loads in test waters and be useful for process control in treatment trains.
| Reference Key |
sherchan2018sensorsnear
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Samendra Sherchan;Syreeta Miles;Luisa Ikner;Hye-Weon Yu;Shane A. Snyder;Ian L. Pepper;Sherchan, Samendra;Miles, Syreeta;Ikner, Luisa;Yu, Hye-Weon;Snyder, Shane A.;Pepper, Ian L.; |
| Journal | sensors |
| Year | 2018 |
| DOI |
10.3390/s18072303
|
| URL | |
| Keywords |
microorganism
monitoring
water quality
water supply
water reuse
online sensors
National Center for Biotechnology Information
NCBI
NLM
MEDLINE
humans
pubmed abstract
nih
national institutes of health
national library of medicine
time factors
water microbiology*
escherichia coli / isolation & purification*
escherichia coli / metabolism
pmid:30012989
pmc6069152
doi:10.3390/s18072303
samendra sherchan
syreeta miles
ian l pepper
adenosine triphosphate / biosynthesis
disinfection / methods
disinfection / standards*
escherichia coli / radiation effects
osmotic pressure
water quality*
|
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.