the effect of abutment surface roughness on the retention of implant-supported crowns cemented with provisional

Clicks: 309
ID: 260176
2012
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Star

Ranked #12 of 26 articles by views in frontiers in environmental science

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Introduction: Surface roughness can increase the retention of castings by ridges and grooves that are microretentive. This study compared the retention of implant-supported crowns when used with 3 different surface roughness abutments and one temporary cement. Methods: Thirty solid abutments (ITI), 4 mm high, were divided into three groups randomly. In the first group, 10 abutments were roughened with sandblast (50-µm aluminum oxide) and in the second group, 10 abutments were roughened with diamond bur. The third group had no surface treatment. Then, thirty implant fixture analogs (ITI) were placed in the center of acrylic cylinders. After that a solid abutment was tightened on the each fixture analog with 35 N/cm force. Thirty base metal crowns were made on the 4 mm ITI abutment analogs using plastic coping. The prepared copings were cemented on the abutments by TempBond temporary cement and finally, crowns were pulled from the abutment in a universal test machine at a cross speed of 0.5cm/min. Results: The mean tensile strength in sandblasted, bur treated, and control group were 64.38±8, 91.37±7.19, and 58.61±1.93, respectively. Bur treated group showed higher tensile strength in comparison with two other groups. Conclusion: Surface modification of implant abutment by diamond bur may be an effective method to increase retention of crown when TempBond is used.
Reference Key
abrisham2012journalthe Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Seyyed Mohammad Abrisham;Farid Shiezadeh;Mohammad Reza Nakhaei;Jalil Ganbarzadeh
Journal frontiers in environmental science
Year 2012
DOI
DOI not found
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.