determination of antioxidant flavonoids in sudanese honey samples by solid phase extraction and high performance liquid chromatography
Clicks: 220
ID: 259041
2009
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Emerging Content
30.0
/100
220 views
30 readers
AI Quality Assessment
Not analyzed
Readership in this journal
EmergingRanked #59 of 235 articles by views in Journal of pharmaceutical and biomedical analysis
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 235 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Flavonoids were extracted by solid phase extraction (SPE) from seven floral honey samples of different botanical origin from different regions of Sudan. The flavonoids were determined by high performance liquid chromatography (HPLC) technique using photo diode array detector (PDA). An isocratic and gradient systems for the resolution, identification and quantification of five flavonoids, namely; quercetin, kaempferol, apigenin, hesperetin and isorhamnetin, were developed. Although the isocratic system resolved the five compounds, however it suffered from interference by the complex mixture of honey samples. The gradient system resolved three of five flavonoids, namely, quercetin, kaempferol, and isorhamnetin, without interference by the complex honey matrix. Two flavonoids, apigenin and hesperetin, were observed to elute at close retention times, which lead to their interference with each other when injected in a mixture; however, absorption wavelength selection was found indicative of the presence or absence of either compound. The quantification of these flavonoids was done through the calibration curves of their standards. The obtained results were compared with reported results.
| Reference Key |
makawi2009e-journaldetermination
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Suzan Zein Alabdeen Makawi;Elrasheed Ahmed Gadkariem;Saad Mohamed Hussein Ayoub |
| Journal | Journal of pharmaceutical and biomedical analysis |
| Year | 2009 |
| DOI |
10.1155/2009/382504
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org