development of carbon fiber-modified electrically conductive concrete for implementation in des moines international airport
Clicks: 164
ID: 259010
2018
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Emerging Content
30.0
/100
164 views
17 readers
AI Quality Assessment
Not analyzed
Readership in this journal
EmergingRanked #19 of 22 articles by views in psilogos
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
This paper reports on the procedures of mix design preparation, production, placement, and performance evaluation of the first electrically conductive concrete (ECON) heated-pavement system (HPS) implemented at a U.S. airport. While ECON has drawn considerable attention as a paving material for multi-functional pavements, including HPS, the majority of ECON HPS applications and studies have been limited to laboratory scale or include materials/methods that do not conform to regulations enforced by airfield construction practices. Carbon fiber-reinforced ECON provides a promising prospective for application in airfield pavements. In this study, ECON mixtures were prepared in the laboratory using varying cementitious materials, aggregate systems, water-to-cementitious ratios, carbon fiber dosages, and admixtures. The results of tests on laboratory-prepared mixes were utilized to find the most suitable ECON mix design for application in an HPS test section at the Des Moines International Airport. The properties of the ECON produced at the concrete plant were measured and compared with equivalent laboratory-prepared samples. The final mix design exhibited electrical resistivity of 115 Ω-cm in the laboratory and 992 Ω-cm in the field, while completely meeting strength and workability requirements. Despite the higher ECON resistivity obtained in large-scale production, the fabricated HPS exhibited desirable performance with respect to deicing and anti-icing operations. The test section was able to generate a 300–350 W/m2 power density and to effectively melt ice/snow with this level of energy. Keywords: Electrically conductive concrete (ECON), Carbon fiber, Mix design, Des Moines International Airport, Heated Pavement, Snow Melting, Deicing
| Reference Key |
sassani2018casedevelopment
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Alireza Sassani;Halil Ceylan;Sunghwan Kim;Ali Arabzadeh;Peter C. Taylor;Kasthurirangan Gopalakrishnan |
| Journal | psilogos |
| Year | 2018 |
| DOI |
DOI not found
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.