methods of identifying, collecting and analysing accelerants in arson fires in the kingdom of saudi arabia

Clicks: 260
ID: 258869
2015
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Star

Ranked #5 of 9 articles by views in iranian journal of microbiology

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
If there is a suspicion of arson, analysis of fire debris and identification of potential accelerants is considered to be one of the most essential examinations of the investigation. The existence of any traces of potential accelerants in a sample taken from the fire scene is crucial in determining whether the fire was started deliberately or not. This study is divided into four parts: the first part describes the most important ignition accelerators which are used in arson fires in Saudi Arabia. The second part is devoted to determining the methods that are used to collect and store trace evidences from fire scenes in Saudi Arabia, if there is a suspicion that accelerants have been used to ignite the fire. The most important techniques used in the extraction and analysis of ignitable liquid residue (ILR) in arson cases are presented in the third section. Finally, the fourth part discusses the problems and difficulties which both experts and employees in The General Department of Forensic Evidence in Saudi Arabia face when collecting and sampling traces as well as some recommendations to address these issues. The results obtained from this study indicate that the most common accelerant used to start fires is gasoline, specifically ‘Octane 91’, followed by kerosene, thereafter diesel and finally paint thinner. Experts are also agreed on the difficulty of obtaining evidence from this type of crime scene, especially after the fire has been extinguished and the scene is released for investigation by the Civil Defense. They also agree that the best technique for extracting and analyzing ignitable liquid residue (ILR) in the solid phase should be Gas Chromatography coupled with Headspace (GC-Headspace). In liquid samples, either Gas Chromatography coupled with Mass Spectroscopy (GC-MS) or Fourier transform infrared (FT- IR) can be used.
Reference Key
dhabbah2015arabmethods Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Abdulrhman M. Dhabbah
Journal iranian journal of microbiology
Year 2015
DOI
10.12816/0017709
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.