predictable duty cycle modulation through coupled pairing of syringes with microfluidic oscillators

Clicks: 170
ID: 258711
2014
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Popular

Ranked #76 of 115 articles by views in chemistryopen

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
The ability to elicit distinct duty cycles from the same self-regulating microfluidic oscillator device would greatly enhance the versatility of this micro-machine as a tool, capable of recapitulating in vitro the diverse oscillatory processes that occur within natural systems. We report a novel approach to realize this using the coordinated modulation of input volumetric flow rate ratio and fluidic capacitance ratio. The demonstration uses a straightforward experimental system where fluid inflow to the oscillator is provided by two syringes (of symmetric or asymmetric cross-sectional area) mounted upon a single syringe pump applying pressure across both syringes at a constant linear velocity. This produces distinct volumetric outflow rates from each syringe that are proportional to the ratio between their cross-sectional areas. The difference in syringe cross-sectional area also leads to differences in fluidic capacitance; this underappreciated capacitive difference allows us to present a simplified expression to determine the microfluidic oscillators duty cycle as a function of cross-sectional area. Examination of multiple total volumetric inflows under asymmetric inflow rates yielded predictable and robust duty cycles ranging from 50% to 90%. A method for estimating the outflow duration for each inflow under applied flow rate ratios is provided to better facilitate the utilization of this system in experimental protocols requiring specific stimulation and rest intervals.
Reference Key
lesher-perez2014micromachinespredictable Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Sasha Cai Lesher-Perez;Priyan Weerappuli;Sung-Jin Kim;Chao Zhang;Shuichi Takayama
Journal chemistryopen
Year 2014
DOI
10.3390/mi5041254
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.