Ex vivo Comparison of 2 Disposable versus a State-of-the-Art Reusable Ureterorenoscope.
Clicks: 259
ID: 25797
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Star Article
62.1
/100
259 views
184 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
StarRanked #4 of 6 articles by views in Urologia internationalis
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
The success of upper urinary tract endoscopy on one hand and the high cost of purchase and maintenance of the scopes on the other hand have driven the development of disposable digital flexible ureterorenoscopy (fURS).We performed an ex vivo comparison of 2 disposable digital fURS from different companies with a state-of-the-art reusable endoscope from another well-established scope manufacturer. The scopes were tested comparing parameters such as instrument handling, irrigation flow, image quality, and deflection. For the disposable scopes, the latter 2 were evaluated both, before and after vigorous stress testing.Expectedly, the most consistent finding among the 3 instruments was the marked decrease on irrigation flow following insertion of a working element, most notably a guidewire. Depth perception and ergonomic handling were comparable in all 3 instruments. Poststress testing revealed a significant loss of upward deflection in both disposable instruments, more so when an auxiliary instrument is inserted into the working channel. However, this did not appear to be the case in downward deflection.To our knowledge, this is the first study that used a vigorous stress testing protocol comparing disposable and reusable fURS. The newer generation disposable scope fared better than the older one. Results are encouraging and indicate that improvements are ongoing and progressing, bringing the quality of disposable scopes to the level that we are used to from our reusable high performance scopes while at the same time avoiding costly damage repairs. Continuous research and evidence-based interpretation of results in the absence of commercial bias are paramount to ensure this ongoing development.
| Reference Key |
bourdoumis2019exurologia
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Bourdoumis, Andreas;El Howairis, Mohammed El Fatih;Stephen, Binu;Buchholz, Noor; |
| Journal | Urologia internationalis |
| Year | 2019 |
| DOI |
10.1159/000502759
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.