an upright eyedrop bottle: accuracy, usage of excess drops, and contamination compared to a conventional bottle

Clicks: 394
ID: 257284
2016
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #11 of 271 articles by views in e3s web of conferences

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 271 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Isaiah J Davies,1 Ninita H Brown,2 Joanne C Wen,3 Sandra S Stinnett,1 Kelsey Kubelick,4,5 Roma P Patel,6 Kristin L Benokraitis,7 Latoya Greene,1 Curry Cheek,1 Kelly W Muir1,8 1Department of Ophthalmology, Duke University School of Medicine, Durham, NC, USA; 2Metrolina Eye Associates, Charlotte, NC, USA; 3Department of Ophthalmology, University of Washington, Seattle, WA, USA; 4Wallace H Coulter Department of Biomedical Engineering, Georgia Institute of Technology, 5Wallace H Coulter Department of Biomedical Engineering, Emory University School of Medicine, Atlanta, Georgia, USA; 6University of California Davis Health System Eye Center, Sacramento, CA, USA; 7EG-GILERO, Durham, NC, USA; 8Health Services Research & Development, Durham VA Medical Center, Durham, NC, USA Purpose: This study tested the feasibility of using an upright eyedrop bottle (UEB), a device designed to assist patients with eyedrop placement without reclining their head. Patients and methods: Experienced eyedrop users were enrolled who answered “yes” to the question, “Do you ever have trouble getting your eyedrops in?” After being shown a multimedia presentation and answering a questionnaire regarding eyedrop usage, participants were observed instilling eyedrops. Participants were instructed to instill a single eyedrop in each eye with both a standard bottle and the UEB. They repeated this process three times. With each trial, the amount of time taken to instill drops was recorded, as well as whether a drop landed in the eye (accuracy), if excess drops were used, and if the bottle tip was contaminated. Results: Forty participants were enrolled, with an average age of 72.4±8.9 years; the majority were females (24 females). Thirty-four participants had been using eyedrops for at least 1 year. The time required to instill eyedrops was significantly less with the UEB in the second and third trials. There was no difference in accuracy between the conventional bottle and the UEB in the left or right eye in any trials. Significantly more participants used excess number of drops while using the conventional bottle in both the left and right eyes in all three trials. The bottle tip was never contaminated with the UEB. Depending on the trial and the eye, the conventional bottle was contaminated by between 42% and 53% of participants. Conclusion: The UEB has the potential to assist patients with eyedrop placement. Although there was no difference in accuracy between the UEB and the conventional bottle, the UEB was associated with less use of excess drops and less contamination of the bottle tip, compared to the conventional bottle. Keywords: glaucoma, compliance, medical devices
Reference Key
ij2016clinicalan Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Davies IJ;Brown NH;Wen JC;Stinnett SS;Kubelick K;Patel RP;Benokraitis KL;Greene L;Cheek C;Muir KW
Journal e3s web of conferences
Year 2016
DOI
DOI not found
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.