study on acoustic emission characteristics of a semirigid base of dense skeleton type during complete uniaxial compression tests

Clicks: 210
ID: 257111
2016
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #69 of 254 articles by views in bulletin of the korean chemical society

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 254 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Acoustic emission testing of semirigid base specimens subjected to uniaxial compression was performed by a mechanical testing machine and AE system to find the AE criterion of the uniaxial compressive failure process of the semirigid base of dense skeleton types. AE counts, cumulative AE energy, and b-value were discussed. Results indicated that the AE parameters could reflect the failure process of semirigid bases of dense skeleton types. The failure process mainly underwent three stages that were divided based on AE parameters into initial stage of development, stable growth stage, and unstable stage. The knees of the AE parameter curve were at 25% and 85% of the ultimate load. The variation of the b-value could indicate the stress and be a precursor to the failure of the specimens. In general terms, a b-value greater than 3.5 indicates that specimens are at the initial stage of development. A b-value between 1 and 2 indicates that the specimens are at the stable growth stage. If the b-value seems to fluctuate and increase, the specimens are at the unstable stage. Moreover, the AE parameters indicated that attaching sensors to the waist of specimens was superior to that at other locations of a specimen.
Reference Key
li2016advancesstudy Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Shengli Li;Guangming Wu;Hao Wu
Journal bulletin of the korean chemical society
Year 2016
DOI
10.1155/2016/9238698
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.