Highly selective extraction and voltammetric determination of the opioid drug buprenorphine via a carbon paste electrode impregnated with nano-sized molecularly imprinted polymer.
Clicks: 229
ID: 25683
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
59.7
/100
229 views
192 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #59 of 75 articles by views in Mikrochimica acta
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
An electrochemical sensor for the opioid drug buprenorphine (BUP) is described. Molecularly imprinted polymer nanoparticles (nanoMIP) were prepared and used to modify a carbon paste electrode (CPE). The BUP-imprinted polymer was synthesized using precipitation polymerization. The resulting polymer along with multiwalled carbon nanotubes (MWCNT) was used to fabricate the modified CPE which exhibited an anodic peak at about +0.73 V (vs. Ag/AgCl) for BUP. The MIP on the CPE functions as selective recognition element with an imprinting factor of 5.6. The assay consists of two-steps, viz. analyte extraction at the electrode surface and differential pulse voltammetric determination of BUP. The effects of various parameters on the electrochemical signal were optimized, and the selectivity of the modified CPE over cross reactants was studied. At optimum experimental conditions, the response is linear in the 1 nM to 50 μM BUP concentration range, and the detection limit is 0.6 nM (at S/N = 3). This method was applied to the determination of BUP in spiked urine with acceptable relative standard deviations (3.2-4.4%). Graphical abstract Schematic representation of buprenorphine (BUP) recognition and voltammetric determination at the surface of carbon paste electrode modified with imprinted polymer and carbon nanotubes.
| Reference Key |
alizadeh2019highlymikrochimica
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Alizadeh, Taher;Atashi, Fatemeh;Akhoundian, Maedeh;Ganjali, Mohammad Reza; |