revealing maximal diameter of upper limb superficial vein with an elevated environmental temperature

Clicks: 163
ID: 255548
2016
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #18 of 21 articles by views in international journal of life sciences and biotechnology

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Ultrasonography is the primary tool for preoperative analysis of vein morphology for fistula creation in patients with end-stage renal disease. This study examines the effect of environmental temperature on the superficial vein size. Superficial veins of thirteen healthy volunteers were marked at three sites: cephalic vein in left lateral arm near cubital fossa, cephalic vein in left forearm at wrist, and basilic vein in left medial arm near cubital fossa. Mean diameters were recorded using ultrasound probe at 26°C and 43°C. Body temperature was increased using a Bair Hugger blanket. Mean values from the two temperatures were analyzed using paired sample t-test. All three superficial vein sites displayed statistically significant increase in diameter when the temperature was increased from 26°C to 43°C. Paired t-test showed p values of 0.001 for cephalic vein at wrist, 0.01 for cephalic vein near cubital fossa, and 0.01 for basilic vein near cubital fossa. This study proved that environmental temperature exerts a statistically significant effect on vein size measured by ultrasound during preoperative assessment for vascular access. Not to the extent of 43°C, the authors would recommend setting the room temperature higher during ultrasound vascular assessment to avoid underestimating the superficial vein size.
Reference Key
irfan2016internationalrevealing Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Hira Irfan;Guo Shen Ooi;May M. Kyin;Pei Ho
Journal international journal of life sciences and biotechnology
Year 2016
DOI
10.1155/2016/8096473
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.