corneal spherical aberration and corneal asphericity after small incision lenticule extraction and femtosecond laser-assisted lasik
Clicks: 320
ID: 255467
2017
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Emerging Content
67.3
/100
320 views
257 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
EmergingRanked #19 of 167 articles by views in chemical reviews
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 167 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Purpose. To investigate corneal spherical aberration and corneal asphericity after small incision lenticule extraction (SMILE) and femtosecond laser-assisted laser in situ keratomileusis (FS-LASIK). Methods. This study enrolled 70 patients having SMILE and 64 subjects receiving FS-LASIK. The preoperative spherical equivalent (SE) was −5.83 ± 1.23 diopters (D) and −6.20 ± 1.52 D, respectively. The uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), SE, corneal spherical aberration, and asphericity over the 6.0 mm cornea were evaluated preoperatively and postoperatively. Results. At 6 months, the UDVA, CDVA, and SE were −0.12 ± 0.11, −0.05 ± 0.05, and −0.16 ± 0.19 D in SMILE and −0.10 ± 0.06, −0.03 ± 0.06, and −0.08 ± 0.25 D in FS-LASIK. There was no difference between groups in the postoperative UDVA, CDVA, or SE (P>0.05). SMILE showed lower inductions of spherical aberration along the anterior surface and the total cornea and less increases in corneal asphericity of the anterior surface postoperatively than FS-LASIK (P<0.01). There were significant correlations between the changes in spherical aberration and corneal asphericity (P<0.001). Conclusions. SMILE and FS-LASIK exhibited excellent visual results and refractive outcomes. SMILE induced less increase in corneal spherical aberration and better preserved the corneal asphericity of the anterior corneal surface than FS-LASIK. Corneal asphericity changes contributed to the corneal spherical aberration changes following SMILE and FS-LASIK.
| Reference Key |
zhang2017journalcorneal
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Hui Zhang;Yan Wang;Hua Li |
| Journal | chemical reviews |
| Year | 2017 |
| DOI |
10.1155/2017/4921090
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.