efficacy and safety of a new single-port model for appendectomy: experimental study on swine
Clicks: 167
ID: 255434
2016
Article Quality & Performance Metrics
Overall Quality
Improving Quality
0.0
/100
Combines engagement data with AI-assessed academic quality
Reader Engagement
Emerging Content
3.9
/100
13 views
13 readers
Trending
AI Quality Assessment
Not analyzed
Abstract
Context: With the cooperation of surgeons and the engineering division of the company Bhio supply© (Esteio-RS, Brazil), a permanent single port was developed. AIMS: An experimental study assessed the safety and efficacy of the device using a swine laparoscopic appendectomy model (right salpingo-oophorectomy). Settings and Design: Experimental randomised study. Materials and Methods: A total of 20 pigs were randomised for the conventional laparoscopic (CL) three-trocar technique or the single Centry port (CPort) with two working channels, aided by a transparietal thread. Operative times, surgical complications, CO2use, and pneumoperitoneal pressure were checked. Pressure and chromopertubation tests assessed the ligatures. Statistical Analysis Used: For quantitative outcomes, the Fisher's exact test analysed the samples to compare the surgeons in each group, the ANOVA test for parametric data (volume and pressure) and the Student's t-test for analysis of the fascial incision length. The binaries and isolated occurrence events were described in percentages.Results: For all cases, pneumoperitoneum was maintained. The CPort group, however, resulted in higher CO2use (26.18 l; standard deviation [SD] ± 11.09) than CL group (5.69 l; SD ± 2.44) (P < 0.01). The mean pressure in CPort group (6.604 mmHg, SD ± 1.793) was comparatively lower than in CL group (7.382 mmHg, SD ± 1.833) (P = 0.363). There was no statistical difference between operative times, ligature safety or adverse surgical events between the different groups and surgeons. Conclusion: The surgical technique used with the single port showed no differences in safety and efficacy. Though it does require more CO2use, its working dynamics did not lead to increased operative times. The results were similar between the two surgeons in the study, suggesting that they can be reproduced.
Abstract Quality Issue:
This abstract appears to be incomplete or contains metadata (262 words).
Try re-searching for a better abstract.
| Reference Key |
olijnyk2016journalefficacy
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;José Gustavo Olijnyk;Paulo Walter Ferreira;Miguel Prestes Nácul;Leandro Totti Cavazzola |
| Journal | it architect |
| Year | 2016 |
| DOI |
10.4103/0972-9941.158951
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.