Accuracy of intraoperative electrophysiological testing in confirming correct cochlear implant electrode positions.
Clicks: 301
ID: 25543
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Popular Article
75.7
/100
301 views
219 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
PopularRanked #3 of 5 articles by views in cochlear implants international
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
: To investigate the accuracy of intraoperative electrophysiological studies in detecting incorrectly positioned electrodes in cochlear implant surgery. : A retrospective chart review. : Tertiary referral centre. : In total, 104 consecutive patients with a mean age of 5 years underwent cochlear implant surgery at our centre between January 2012 and December 2013. All patients were implanted with Cochlear Nucleus Freedom implants. : A retrospective study to compare intraoperative neural response telemetry (NRT), impedance and electrode position using Stenver's transorbital plain X-ray view. : Intraoperative electrophysiological tests for patients with Cochlear Nucleus Freedom implants showed 97% sensitivity and 100% specificity compared with postoperative X-ray imaging. : NRT results for the position of cochlear implants were very accurate when checked by X-ray imaging showing that this technique is sufficient in most cases. Stenver's plain X-ray view is needed in complicated cases with abnormal NRT testing or difficult electrode insertion.
| Reference Key |
al-omari2019accuracycochlear
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Al Omari, Ahmad;Nuseir, Amjad;Ata, Majid Bani;Khasawneh, Laith;Alhowary, Ala A;Alzoubi, Firas; |
| Journal | cochlear implants international |
| Year | 2019 |
| DOI |
10.1080/14670100.2019.1656904
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.