continuous low-maintenance co2/ch4/h2o measurements at the zotino tall tower observatory (zotto) in central siberia
Clicks: 108
ID: 255087
2010
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Popular Article
30.0
/100
108 views
22 readers
AI Quality Assessment
Not analyzed
Readership in this journal
PopularRanked #152 of 183 articles by views in bioorganic & medicinal chemistry
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 183 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
To monitor the continental carbon cycle, a fully automated low maintenance measurement system is installed at the Zotino Tall Tower Observatory in Central Siberia (ZOTTO, 60°48' N, 89°21' E) since April 2009. A cavity ring-down spectroscopy (CRDS) analyzer continuously measures carbon dioxide (CO2) and methane (CH4) from six heights up to 301 m a.g.l. Buffer volumes in each air line remove short term CO2 and CH4 mixing ratio fluctuations associated with turbulence, and allow continuous, near-concurrent measurements from all tower levels. Instead of drying the air sample, the simultaneously measured water vapor is used to correct the dilution and pressure-broadening effects for the accurate determination of dry air CO2 and CH4 mixing ratios. The stability of the water vapor correction was demonstrated by repeated laboratory and field tests. The effect of molecular adsorption in the wet air lines was shown to be negligible. The low consumption of four calibration tanks that need recalibration only on decadal timescale further reduces maintenance. The measurement precision (accuracy) of 0.04 ppm (0.09 ppm) for CO2 and 0.3 ppb (1.5 ppb) for CH4 is compliant with the WMO recommendations. The data collected so far (until April 2010) reveals a seasonal cycle amplitude for CO2 of 30.4 ppm at the 301 m level.
| Reference Key |
hfer2010atmosphericcontinuous
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;A. Höfer;C. Kaiser;J. V. Lavrič;T. Seifert;O. Kolle;C. Gerbig;H. Chen;J. Winderlich;M. Heimann |
| Journal | bioorganic & medicinal chemistry |
| Year | 2010 |
| DOI |
10.5194/amt-3-1113-2010
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.