preliminary validation of column-averaged volume mixing ratios of carbon dioxide and methane retrieved from gosat short-wavelength infrared spectra
Clicks: 81
ID: 253646
2011
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Popular Article
24.0
/100
81 views
7 readers
AI Quality Assessment
Not analyzed
Readership in this journal
PopularRanked #168 of 183 articles by views in bioorganic & medicinal chemistry
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 183 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Column-averaged volume mixing ratios of carbon dioxide and methane retrieved from the Greenhouse gases Observing SATellite (GOSAT) Short-Wavelength InfraRed observation (GOSAT SWIR <i>X</i><sub>CO<sub>2</sub></sub> and <i>X</i><sub>CH<sub>4</sub></sub>) were compared with the reference calibrated data obtained by ground-based high-resolution Fourier Transform Spectrometers (g-b FTSs) participating in the Total Carbon Column Observing Network (TCCON). <br><br> Preliminary results are as follows: the GOSAT SWIR <i>X</i><sub>CO<sub>2</sub></sub> and <i>X</i><sub>CH<sub>4</sub></sub> (Version 01.xx) are biased low by 8.85 ± 4.75 ppm (2.3 ± 1.2 %) and 20.4 ± 18.9 ppb (1.2 ± 1.1 %), respectively. The standard deviation of the GOSAT SWIR <i>X</i><sub>CO<sub>2</sub></sub> and <i>X</i><sub>CH<sub>4</sub></sub> is about 1 % (1 σ) after correcting the negative biases of <i>X</i><sub>CO<sub>2</sub></sub> and <i>X</i><sub>CH<sub>4</sub></sub> by 8.85 ppm and 20.4 ppb, respectively. The latitudinal distributions of zonal means of the GOSAT SWIR <i>X</i><sub>CO<sub>2</sub></sub> and <i>X</i><sub>CH<sub>4</sub></sub> show similar features to those of the g-b FTS data except for the negative biases in the GOSAT data.
| Reference Key |
morino2011atmosphericpreliminary
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;I. Morino;O. Uchino;M. Inoue;Y. Yoshida;T. Yokota;P. O. Wennberg;G. C. Toon;D. Wunch;C. M. Roehl;J. Notholt;T. Warneke;J. Messerschmidt;D. W. T. Griffith;N. M. Deutscher;V. Sherlock;B. Connor;J. Robinson;R. Sussmann;M. Rettinger |
| Journal | bioorganic & medicinal chemistry |
| Year | 2011 |
| DOI |
10.5194/amt-4-1061-2011
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.