treatment optimisation using external beam radiation in gynaecological cancers

Clicks: 117
ID: 252874
2004
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Popular

Ranked #56 of 77 articles by views in annales pharmaceutiques francaises

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
The majority of patients with gynaecological cancers present with advanced stages in which external beam radiation forms a major component of the treatment. These patients undergo simulation for treatment planning prior to radiation. Currently the lower extent of the disease is evaluated by vaginal examination and marked using a lead wire on the anterior abdominal wall in the pelvic region. A 2 cm margin inferior to this level is used as the lower border of the treatment field. The suggested modified technique includes the placement of an indigenously designed perspex vaginal obturator with graduations at 1 cm distance from its tip. Following vaginal examination the obturator can be inserted into the vagina and fixed at the predefined length using a fixation device. The radio-opaque markers can be seen even in the lateral films. Twentyfive consecutive patients underwent the procedure and the differences between the two methods of marking the lower border were calculated. The external lead wire was inferior to the internal obturator in 19 patients (76%) ranging from 0.5 cm to 3 cm (median 1.5 cm, mean 1.37 cm). It was at the same level in 4 patients (16%) and 1 cm superior to the internal obturator in 2 (8%). With the modified technique using the internal obturator application for delineating the lower border of vaginal disease or vault, it was possible to decrease the length of field thereby reducing the chances of treatment-related toxicity, especially groin and vulval reactions, as well as avoiding treatment interruptions.
Reference Key
sharma2004southtreatment Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;V. Sharma;U. Majeed;D. Joseph;S. Lindikile;N. Madhoo;H. Copelyn;J. Kotzen;M. Mohiuddin;B. Donde;D. van der Merwe
Journal annales pharmaceutiques francaises
Year 2004
DOI
10.4102/sajr.v8i3.120
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.