time dependent profile retrieval of uv/vis absorbing radicals from balloon-borne limb measurements – a case study on no2 and o3

Clicks: 204
ID: 251723
2010
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Popular

Ranked #87 of 183 articles by views in bioorganic & medicinal chemistry

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 183 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
A new "Bayesian" minimization algorithm for the retrieval of the diurnal variation of UV/vis absorbing radicals (O3, NO2, BrO, OClO and HONO) from balloon-borne limb scattered skylight observations is discussed. The method evaluates spectroscopic measurements in combination with radiative transfer calculations to drive a mathematical inversion on a discrete time and height grid. Here, the proposed method is applied to data obtained during two deployments of the mini-DOAS instrument on different balloon payloads in northern Brazil in June 2005. The retrieval is tested by comparing the inferred profiles to in-situ ozone sounding data and to measurements of the ENVISAT/SCIAMACHY satellite instrument performed during a collocated overpass. The comparison demonstrates the strength and validity of our approach. In particular for time-varying radical concentrations, photochemical corrections due to temporal mismatch of the corresponding observations are rendered dispensable. Thus, limb scanning UV/vis spectrometry from balloon platforms offers a more direct and concise approach for satellite validation of radical measurements than solar occultation measurements. Furthermore, monitoring of the diurnal variation of stratospheric radicals allows us to constrain photochemical parameters which are critical for stratospheric ozone chemistry, such as the photolysis frequency of N2O5 by observations of the diurnal variation of NO2.
Reference Key
schofield2010atmospherictime Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors
Journal bioorganic & medicinal chemistry
Year 2010
DOI
10.5194/amt-3-933-2010
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.