the noise control prioritizing index in a tire manufacturing company

Clicks: 355
ID: 250502
2017
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #2 of 6 articles by views in 2017 10th international conference on contemporary computing, ic3 2017

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Introduction; controlling noise pollution in an indoor environment has always been faced with administrative and financial constraints. Prioritizing in a scientific manner is a useful approach in dealing with such problems. The aim of the present study was to determine the noise control prioritizing index (NCPI) in various units from a tire manufacturing company.   Methods; the sound pressure levels in various units were determined in accordance with ISO 9612 standard. The index was a function of three parameters; the number of people exposed of the noise, exposure time, and a weighting factor corresponding to the sound pressure level. The distribution of noise levels on the unit with the highest priority was depicted using Surfer ver.10.   Results; according to the environmental measurements, 22.9% of the investigated stations had a noise level in the danger zone and other 77.1% was in the caution zone. No station was in the safe zone. The sound pressure level had a range between 69.9-104.7 dB(A). Among the investigated units, the curing unit with 20 employees had the highest priority of noise control (NCPI=1.369).   Conclusion; the results of the present study indicated that using an index resulted from a combination of various parameters affecting the noise pollution, we would be able to prioritize units for implementing noise pollution control confidently. The results of the present study are applicable to all similar industrial settings.
Reference Key
golmohammadi2017muhandis-ithe Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Rostam Golmohammadi;Forough Moazaz;Mohsen Aliabadi
Journal 2017 10th international conference on contemporary computing, ic3 2017
Year 2017
DOI
DOI not found
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.