measurements of wind turbulence parameters by a conically scanning coherent doppler lidar in the atmospheric boundary layer
Clicks: 105
ID: 248931
2017
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Emerging Content
30.0
/100
105 views
25 readers
AI Quality Assessment
Not analyzed
Readership in this journal
EmergingRanked #147 of 183 articles by views in bioorganic & medicinal chemistry
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 183 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
The method and results of lidar studies of spatiotemporal variability of wind
turbulence in the atmospheric boundary layer are reported. The measurements
were conducted by a Stream Line pulsed coherent Doppler lidar (PCDL) with the use of conical scanning by a probing beam around the vertical axis. Lidar data are used to estimate the kinetic energy of turbulence, turbulent energy
dissipation rate, integral scale of turbulence, and momentum fluxes. The
dissipation rate was determined from the azimuth structure function of radial
velocity within the inertial subrange of turbulence. When estimating the
kinetic energy of turbulence from lidar data, we took into account the
averaging of radial velocity over the sensing volume. The integral scale of
turbulence was determined on the assumption that the structure of random
irregularities of the wind field is described by the von Kármán
model. The domain of applicability of the used method and the accuracy of the estimation of turbulence parameters were determined. Turbulence parameters estimated from Stream Line lidar measurement data and from data of a sonic anemometer were compared.
| Reference Key |
smalikho2017atmosphericmeasurements
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;I. N. Smalikho;V. A. Banakh |
| Journal | bioorganic & medicinal chemistry |
| Year | 2017 |
| DOI |
10.5194/amt-10-4191-2017
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.