results of modified dual onlay bone graft in nonunion with large defect

Clicks: 149
ID: 248203
2003
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #97 of 133 articles by views in 2017 ieee international conference on communication, networks and satellite, comnetsat 2017 - proceedings

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 133 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Background: Nonunions with large defect is a problem, especially in large defects with infection this problem is more serious. Due to war and grave accidents in our country, we have encountered with these difficulties and in future time will also. Methods: We modified D.O.B.G by using plate in one side of large defect and metal plate on another side, and fixed these plates using screws anchoring the distal and proximal segments of nonunion sites rigidly. The technique is very simple, reliable, less morbidity in donor site, short operation time and needn's especial instruments and equipments. We use this technique in 146 patients and follow one hundred of thems for 2.5 yrs (mean time) clinically and radiological. Results: Union rate was ninety percent. Due to rigid fixation and early R.O.M of joints the final limbs function were excellent (comparison with others technique). Discussion: Modified D.O.B.G is the choice technique for nonunion with lange defect especially in metaphysis. because of rigid fixation results early R.O.M and good limb function, high union rate, short operation time, simple technique and less morbidity in donor site.
Reference Key
nazem2003journalresults Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;KH.A NAZEM;A.B TAVAKOLI
Journal 2017 ieee international conference on communication, networks and satellite, comnetsat 2017 - proceedings
Year 2003
DOI
DOI not found
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.