contrast sensitivity after zyoptix tissue saving lasik and standard lasik for myopia with 6-month followup
Clicks: 260
ID: 247442
2011
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Emerging Content
30.0
/100
260 views
18 readers
AI Quality Assessment
Not analyzed
Readership in this journal
EmergingRanked #38 of 167 articles by views in chemical reviews
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 167 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
This control-matched comparative study evaluated changes in contrast sensitivity after Zyoptix tissue-saving (TS) LASIK and Planoscan standard LASIK (Technolas 217z, Bausch & Lomb) for myopia 6 months postoperatively. 102 TS LASIK-treated eyes were matched with 102 standard LASIK-treated eyes (divided into low, moderate, and high groups). There were no significant differences in refraction outcomes between the groups postoperatively. In high group, a significant reduction in contrast sensitivity after TS LASIK was found at high spatial frequencies (P<.05) under photopic conditions and at middle to high spatial frequencies (P<.05) under mesopic conditions. And significant reduction was also found in standard LASIK at high spatial frequency (P<.05) under mesopic conditions. The reduction was significantly lower in TS LASIK than that in standard LASIK at high spatial frequencies (P<.05) under mesopic conditions. TS LASIK was prone to reduce mesopic contrast sensitivity of high myopia at high spatial frequencies.
Abstract Quality Issue:
This abstract appears to be incomplete or contains metadata (73 words).
Try re-searching for a better abstract.
| Reference Key |
zhao2011journalcontrast
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Li-Quan Zhao;Huang Zhu |
| Journal | chemical reviews |
| Year | 2011 |
| DOI |
10.1155/2011/839371
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.